메뉴 건너뛰기

This is a list of discontinued products.

SIMATICHMIThinClientEx2.jpg

Overview

SIMATIC HMI Thin Client Ex2 with international approvals for operator control and monitoring in hazardous areas.

 

Application

The SIMATIC HMI Thin Client Ex2 is designed for use as an operator station for terminal and client applications in hazardous areas, and in particular for applications for which the performance of the SIMATIC HMI Panel PC Ex is insufficient, or when the server is located in a protected area of the plant. The widely-used RDP and Real VNC protocols are supported.

Together with the digital KVM Box, the device functions as a flexible monitor with touch functionality for PCs e.g. in control rooms.

 

Integration

Integrated interfaces of SIMATIC HMI Thin Client Ex2:

  • 10/100 Mbit 100 base TX (Ex e) or 100 base FX (Ex op is) network
  • 1 x RS232 or 1 x RS422/485
  • 4 x USB 2.0 (2 x Ex I, 2 x Ex e ( Zone 1 version) and/or 2 x Ex nA ( Zone 2 version))
 

Technical specifications

 

SIMATIC HMI Thin Client Ex2

General features

 

Design

Thin Client built-in unit, available in protective enclosure as an option

Front

15" and 19" display

Operation

Touch with 8 function keys

MTBF backlight

50 000 h

Operating system

Windows 10 Enterprise 2016 LTSB

Mass storage

integrated, 64 GB SSD

Power supply

24 V DC, max. 2.1 A (19")

Interfaces

 

Ethernet

100 Mbit Ex e, or alternatively fiber-optics 100 Mbit (SC) Ex op is

USB 2.0

2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA (Zone 2)

Serial

1 x RS232 or 1 x RS422/485

Ambient conditions

 

Degree of protection

IP66 at front, IP65 at rear, IP66 in protective enclosure

Ambient temperature during operation

-20 °C ... + 50 °C, (cold start -10 °C) with optional auxiliary heater down to -30 °C

Relative humidity during operation

90 % at 40 °C, no condensation

Approvals/directives

 

Devices in "Zone 1" version

 

ATEX directive 94/9/EC

 
  • Network 10/100 Base-Tx

II 2 (2) G Ex d e ia ib mb [ia ib] IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C Db IP66

  • Network 10/100 Base-Fx

II 2 (2) G Ex d e ia ib mb [ia ib op is] IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC T80°C Db IP66

IECEx

 
  • Network 10/100 Base-Tx

Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66

  • Network 10/100 Base-Fx

Ex d e ia ib mb [ia ib op is] IIC T4 Gb
Ex ia tb [ia ib op is] IIIC T80°C Db IP66

GOST-R

 
  • Network 10/100 Base-Tx

2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66

  • Network 10/100 Base-Fx

2 Ex d e ia ib mb [iaibopis] IIC T4
 DIP A21 TA80°C, IP66

CSA

Ex d e ia ib mb [ia ib] IIC T4 Gb, Type 4X, IP66
Class II, Division 1, Groups E, F, G, T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66

KGS

Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66

InMetro

 
  • Network 10/100 Base-Tx

Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66

  • Network 10/100 Base-Fx

Ex d e ia ib mb [ia ib op is] IIC T4 Gb
Ex ia tb [ia ib op is] IIIC T80°C Db IP66

Devices in version "Zone 2"

 

ATEX directive 94/9/EC

 
  • Network 10/100 Base-Tx

II 3 (2/3) G Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66

  • Network 10/100 Base-Fx

II 3 (2/3) G Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66

IECEx

 
  • Network 10/100 Base-Tx

Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc
Ex ia tc [ib Db] [ic]  IIIC T80°C Dc IP66

  • Network 10/100 Base-Fx

Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66

GOST-R

 
  • Network 10/100 Base-Tx

2 Ex de i a ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66

  • Network 10/100 Base-Fx

2 Ex de i a ib mb nA [ibopis][ic] IIC T4
DIP A21 TA80°C, IP66

CSA

Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G, T80°C; Ex ia tc [ib ic] IIIC
T80°C Dc, IP66

InMetro

 
  • Network 10/100 Base-Tx

Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc
Ex ia tc [ib Db] [ic]  IIIC T80°C Dc IP66

  • Network 10/100 Base-Fx

Ex d e ia ib mb nA [ib op is Gb] IIC T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66

Protocols

RDP, RealVNC

Digital KVM switch

Input: DVI / VGA, PS/2 / USB,
output: RJ45 (IP network)

Dimensions

 

Mounting dimensions (W x H x D) in mm

15": 427.5 x 327.5 x 165
19": 522.5 x 412.5 x 165

Front dimensions in mm

15": 440 x 340
19": 535 x 425

Weight

15": 15 kg, 19": 23 kg


 
 

Dimensional drawings

Legend:

h = Mounting clamp (10 x)

i = Clamping frame

j = Control cabinet or enclosure

All dimensions in mm. For mounting cut-out see technical specifications.

SIMATIC HMI Thin Client Ex 15"

15" touch front

Width in mm

Height in mm

Depth in mm

Operating unit

440

340

165

Installation cutout

427.5 ± 0.5

327.5 ± 0.5

-


 

SIMATIC HMI Thin Client Ex 19"

19" touch front

Width in mm

Height in mm

Depth in mm

Operating unit

535

425

165

Installation cutout

522 ± 0.5

412.5 ± 0.5

-


 

 

 

More information

More information is available on the internet at:

http://www.siemens.com/simatic-hmi-ex

경기도 용인시 기흥구 용구대로 1855번길 95(상갈동) (주)에버텍 l 대표자 : 이승진 l 사업자등록번호 : 671-88-00213
: 031-287-6361    : 031-287-6362    : sales@yesevt.com

© k2s0o1d4e0s2i1g5n. All Rights Reserved