메뉴 건너뛰기

SIMATIC Box PCs provide mechanical engineers, plant engineers and control cabinet makers with particularly rugged industrial PC systems for use in powerful yet compact applications.

Overview

SIMATIC IPC127E: Ultra-compact IoT gateway for data collection, pre-processing, and forwarding of the data

Thanks to the ultra-compact enclosure, which has a volume of just 0.3 liters, the SIMATIC IPC127E can be easily – even subsequently – integrated into the control cabinet or directly on the machine with minimal space requirements.

The enclosed all-metal enclosure enables the new industrial PC to be used flexibly and maintenance-free even under harsh conditions. Thus the SIMATIC IPC127E makes it possible to reliably record / collect / process / transfer data directly in the production environment and can be flexibly used as an IoT gateway between the cloud or the corporate IT level and production. Thanks to pre-configured versions, the right product is available to users in a very short time.

 

Benefits

High-performance data processing with extremely compact design

  • Current CPU technology of the Intel-Apollo-Lake series
  • 2-core: Intel E3930 and 4-core: Intel E3940
  • Power consumption <= 15 W, i.e. low heat dissipation in the enclosure/control cabinet
  • Wake-on-LAN for remote-controlled switching between standby and active state

High degree of industrial functionality for implementing an embedded solution

  • Solid-state drive as rugged mass storage: 32 / 64 / 128 GB
  • 2x / 3x Gbit Ethernet (teaming-capable); PROFINET with RT functionality (via Standard Ethernet)
  • 2x / 4x USB 3.0 ports
  • 1x DisplayPort as graphics connection
  • Windows 10 LTSB 2016 incl. the embedded features such as Unified Write Filter (UWF)

High system availability in order to reduce the risk of potential failures and maintenance costs

  • Maintenance-free since there are no rotating parts (fans, HDD)
  • Self-diagnostics by means of local diagnostics software SIMATIC IPC DiagBase

Optimum flexibility for adaptation to the machine

  • Flexible mounting (DIN rail and wall mounting)
  • In all vertical installation positions
  • Minimal space requirements (installation volume approx. 0.3 liters; integrated 24 V DC industrial power supply)
  • Up to 50 °C ambient temperature; dust protection due to closed enclosure
  • LEDs for efficient self-diagnostics; optimized for headless operation

High investment security in order to reduce engineering costs

  • Long-term availability: Service & Support period of 8 – 10 years after market launch
 

Application

Diverse range of applications, for example:

  • IoT gateway for the acquisition / collection / processing / transmission of data
  • Integration of machines in Cloud/Edge solutions
  • / retrofitting of digitalization tasks in brownfield systems
  • Simple visualization tasks
 

Design

Basic design
  • All-metal enclosure, resistant to vibrations and shocks, also with high electromagnetic compatibility
    • Basic version
    • Extended version
  • Industrial power supply
    • 24 V DC (19.2 to 28.8 V; without electrical isolation)
  • Graphics connection DisplayPort
    • Resolution: Up to 4 096 x 2 160 pixels
  • Interfaces (accessible from one side):
    • Basis: 2x LAN 10/100/1000 Mbps Ethernet interface (RJ45); 2 x USB V3.0
    • Extended: 3x LAN 10/100/1000 Mbps Ethernet interface (RJ45); 4 x USB V3.0
  • Fieldbus
    • PROFINET Realtime via Standard Ethernet interface
Design versions
  • Processor/main memory configuration:
    • Intel Atom E3930, 1.3 GHz, Dual Core / 2 GB
    • Intel Atom E3940, 1.6 GHz, Quad Core / 4 GB
  • Drives:
    • Solid-state drive 32, M.2, internal
    • Solid-state drive 64, M.2, internal
    • Solid-state drive 128, M.2, internal
    • SSDs Power-Loss-Protection
  • Pre-installed operating systems:
    • Windows 10 IoT Enterprise LTSB 2016, MUI, 64-bit
Integrated diagnostics DiagBase
  • Integrated, parameterizable monitoring functions (program execution/watchdog, internal enclosure temperature, mass storage)
 

Technical specifications

Article number

6AG4021-0AA11-0AA0

6AG4021-0AA12-0BA0

6AG4021-0AB11-0BA0

6AG4021-0AB12-0CA0

 

SIMATIC IPC127E

SIMATIC IPC127E

SIMATIC IPC127E

SIMATIC IPC127E

Installation type/mounting

 

 

 

 

Design

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Supply voltage

 

 

 

 

Type of supply voltage

24 V DC

24 V DC

24 V DC

24 V DC

Mains buffering

 

 

 

 

  • ● Mains/voltage failure stored energy time

5 ms

5 ms

5 ms

5 ms

Processor

 

 

 

 

Processor type

Intel Atom E3930, 1.3 GHz, 2 cores

Intel Atom E3930, 1.3 GHz, 2 cores

Intel Atom E3940, 1.6 GHz, 4 cores

Intel Atom E3940, 1.6 GHz, 4 cores

Drives

 

 

 

 

SSD

Yes; 32 GB

Yes; 64 GB

Yes; 64 GB

Yes; 128 GB

Memory

 

 

 

 

Type of memory

DDR4

DDR4

DDR4

DDR4

Main memory

2 GB RAM

2 GB RAM

4 GB RAM

4 GB RAM

Interfaces

 

 

 

 

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

3; 3x Ethernet (RJ45)

2; 2x RJ45 (independent)

3; 3x Ethernet (RJ45)

Number of PROFINET interfaces

2

3

2

3

USB port

2x USB 3.0

4x USB 3.0

2x USB 3.0

4x USB 3.0

Connection for keyboard/mouse

USB / USB

USB / USB

USB / USB

USB / USB

Video interfaces

 

 

 

 

  • ● Graphics interface

1x DisplayPort

1x DisplayPort

1x DisplayPort

1x DisplayPort

Industrial Ethernet

 

 

 

 

  • ● Industrial Ethernet interface

2x Ethernet (RJ45)

3x Ethernet (RJ45)

2x Ethernet (RJ45)

3x Ethernet (RJ45)

  • — 100 Mbps

Yes

Yes

Yes

Yes

  • — 1000 Mbps

Yes

Yes

Yes

Yes

Protocols

 

 

 

 

Protocols (Ethernet)

 

 

 

 

  • ● TCP/IP

Yes

Yes

Yes

Yes

Integrated Functions

 

 

 

 

Monitoring functions

 

 

 

 

  • ● Temperature monitoring

Yes

Yes

Yes

Yes

  • ● Watchdog

Yes

Yes

Yes

Yes

  • ● Status LEDs

1x power, 3x user

1x power, 3x user

1x power, 3x user

1x power, 3x user

  • ● Fan

No

No

No

No

EMC

 

 

 

 

Interference immunity against discharge of static electricity

 

 

 

 

  • ● Interference immunity against discharge of static electricity

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

  • ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

 

 

 

 

  • — Test voltage at air discharge

8 kV

8 kV

8 kV

8 kV

  • — Test voltage at contact discharge

6 kV

6 kV

6 kV

6 kV

Interference immunity against high-frequency electromagnetic fields

 

 

 

 

  • ● Interference immunity against high frequency radiation

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

Interference immunity to cable-borne interference

 

 

 

 

  • ● Interference immunity on supply cables

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

  • ● Interference immunity on signal cables >30m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

  • ● Interference immunity on signal cables < 30m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

Interference immunity to magnetic fields

 

 

 

 

  • ● Interference immunity to magnetic fields at 50 Hz

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

Emission of conducted and non-conducted interference

 

 

 

 

  • ● Interference emission via line/AC current cables

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

Standards, approvals, certificates

 

 

 

 

Approval

CE, UL

CE, UL

CE, UL

CE, UL

CE mark

Yes

Yes

Yes

Yes

UL approval

Yes

Yes

Yes

Yes

Dust protection

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Ambient conditions

 

 

 

 

Ambient temperature during operation

 

 

 

 

  • ● Ambient temperature during operation

0 °C up to 55 °C

0 °C up to 55 °C

0 °C up to 55 °C

0 °C up to 55 °C

Ambient temperature during storage/transportation

 

 

 

 

  • ● min.

-20 °C

-20 °C

-20 °C

-20 °C

  • ● max.

70 °C

70 °C

70 °C

70 °C

Relative humidity

 

 

 

 

  • ● Relative humidity

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

Vibrations

 

 

 

 

  • ● Vibration resistance during operation acc. to IEC 60068-2-6

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Shock testing

 

 

 

 

  • ● Shock load during operation

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Operating systems

 

 

 

 

pre-installed operating system

 

 

 

 

  • ● Windows 10 Enterprise

No

No

No

No

Dimensions

 

 

 

 

Width

85 mm

85 mm

85 mm

85 mm

Height

85 mm

104 mm

85 mm

104 mm

Depth

41 mm

41 mm

41 mm

41 mm

 

Article number

6AG4021-0AA11-1BA0

6AG4021-0AB11-1BA0

6AG4021-0AB11-1CA0

6AG4021-0AB12-1BA0

6AG4021-0AB12-1CA0

 

SIMATIC IPC127E

SIMATIC IPC127E

SIMATIC IPC127E

SIMATIC IPC127E

SIMATIC IPC127E

Installation type/mounting

 

 

 

 

 

Design

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Supply voltage

 

 

 

 

 

Type of supply voltage

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

Mains buffering

 

 

 

 

 

  • ● Mains/voltage failure stored energy time

5 ms

5 ms

5 ms

5 ms

5 ms

Processor

 

 

 

 

 

Processor type

Intel Atom E3930, 1.3 GHz, 2 cores

Intel Atom E3940, 1.6 GHz, 4 cores

Intel Atom E3940, 1.6 GHz, 4 cores

Intel Atom E3940, 1.6 GHz, 4 cores

Intel Atom E3940, 1.6 GHz, 4 cores

Drives

 

 

 

 

 

SSD

Yes; 64 GB

Yes; 64 GB

Yes; 128 GB

Yes; 64 GB

Yes; 128 GB

Memory

 

 

 

 

 

Type of memory

DDR4

DDR4

DDR4

DDR4

DDR4

Main memory

2 GB RAM

4 GB RAM

4 GB RAM

4 GB RAM

4 GB RAM

Interfaces

 

 

 

 

 

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

3; 3x Ethernet (RJ45)

3; 3x Ethernet (RJ45)

Number of PROFINET interfaces

2

2

2

3

3

USB port

2x USB 3.0

2x USB 3.0

2x USB 3.0

4x USB 3.0

4x USB 3.0

Connection for keyboard/mouse

USB / USB

USB / USB

USB / USB

USB / USB

USB / USB

Video interfaces

 

 

 

 

 

  • ● Graphics interface

1x DisplayPort

1x DisplayPort

1x DisplayPort

1x DisplayPort

1x DisplayPort

Industrial Ethernet

 

 

 

 

 

  • ● Industrial Ethernet interface

2x Ethernet (RJ45)

2x Ethernet (RJ45)

2x Ethernet (RJ45)

3x Ethernet (RJ45)

3x Ethernet (RJ45)

  • — 100 Mbps

Yes

Yes

Yes

Yes

Yes

  • — 1000 Mbps

Yes

Yes

Yes

Yes

Yes

Protocols

 

 

 

 

 

Protocols (Ethernet)

 

 

 

 

 

  • ● TCP/IP

Yes

Yes

Yes

Yes

Yes

Integrated Functions

 

 

 

 

 

Monitoring functions

 

 

 

 

 

  • ● Temperature monitoring

Yes

Yes

Yes

Yes

Yes

  • ● Watchdog

Yes

Yes

Yes

Yes

Yes

  • ● Status LEDs

1x power, 3x user

1x power, 3x user

1x power, 3x user

1x power, 3x user

1x power, 3x user

  • ● Fan

No

No

No

No

No

EMC

 

 

 

 

 

Interference immunity against discharge of static electricity

 

 

 

 

 

  • ● Interference immunity against discharge of static electricity

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2

  • ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

 

 

 

 

 

  • — Test voltage at air discharge

8 kV

8 kV

8 kV

8 kV

8 kV

  • — Test voltage at contact discharge

6 kV

6 kV

6 kV

6 kV

6 kV

Interference immunity against high-frequency electromagnetic fields

 

 

 

 

 

  • ● Interference immunity against high frequency radiation

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

10 V/m, 80 MHz to 2 GHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 GHz to 2.7 GHz, 80 % AM acc. to IEC 61000-4-3; 10 V, 10 kHz to 80 MHz, 80 % AM acc. to IEC 61000-4-6

Interference immunity to cable-borne interference

 

 

 

 

 

  • ● Interference immunity on supply cables

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4; burst); ±0,5 kV (according to IEC 61000-4-5; surge pulse/line to line); ±1 kV (according to IEC 61000-4-5; surge pulse/line to ground)

  • ● Interference immunity on signal cables >30m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

±2 kV acc. to IEC 61000-4-5, surge, length > 30 m

  • ● Interference immunity on signal cables < 30m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m

Interference immunity to magnetic fields

 

 

 

 

 

  • ● Interference immunity to magnetic fields at 50 Hz

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

Emission of conducted and non-conducted interference

 

 

 

 

 

  • ● Interference emission via line/AC current cables

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

EN 61000-6-4:2007 +A1:2011 (industrial environments), EN 61000-6-3:2007 +A1:2011 (residential environments), CISPR 22 Class B, FCC Class A

Standards, approvals, certificates

 

 

 

 

 

Approval

CE, UL

CE, UL

CE, UL

CE, UL

CE, UL

CE mark

Yes

Yes

Yes

Yes

Yes

UL approval

Yes

Yes

Yes

Yes

Yes

Dust protection

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Ambient conditions

 

 

 

 

 

Ambient temperature during operation

 

 

 

 

 

  • ● Ambient temperature during operation

0 °C up to 55 °C

0 °C up to 55 °C

0 °C up to 55 °C

0 °C up to 55 °C

0 °C up to 55 °C

Ambient temperature during storage/transportation

 

 

 

 

 

  • ● min.

-20 °C

-20 °C

-20 °C

-20 °C

-20 °C

  • ● max.

70 °C

70 °C

70 °C

70 °C

70 °C

Relative humidity

 

 

 

 

 

  • ● Relative humidity

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

5 ... 85 % at 30 °C, no condensation

Vibrations

 

 

 

 

 

  • ● Vibration resistance during operation acc. to IEC 60068-2-6

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Tested according to IEC 6068-2-6; 5 Hz to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9,8 m/s²

Shock testing

 

 

 

 

 

  • ● Shock load during operation

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Operating systems

 

 

 

 

 

Operating system

Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

pre-installed operating system

Yes

Yes

Yes

Yes

Yes

pre-installed operating system

 

 

 

 

 

  • ● Windows 10

Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

 

 

 

 

  • ● Windows 10 Enterprise

Yes

Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI

Dimensions

 

 

 

 

 

Width

85 mm

85 mm

85 mm

85 mm

85 mm

Height

85 mm

85 mm

85 mm

104 mm

104 mm

Depth

41 mm

41 mm

41 mm

41 mm

41 mm

 

More information

Additional information is available on the Internet at:

http://www.siemens.com/simatic-ipc

경기도 용인시 기흥구 용구대로 1855번길 95(상갈동) (주)에버텍 l 대표자 : 이승진 l 사업자등록번호 : 671-88-00213
: 031-287-6361    : 031-287-6362    : sales@yesevt.com

© k2s0o1d4e0s2i1g5n. All Rights Reserved