메뉴 건너뛰기

This is a list of discontinued products.

377E.jpg

 

 

Overview

SIMATIC IPC377E

Based on Intel Celeron process technology, the SIMATIC IPC377E Box PC represents a new IPC platform which has been specifically developed for cost-optimized, PC-based applications in industrial and industry-oriented environments.

The SIMATIC IPC377E Panel PC is characterized by industrial touch displays in the sizes 12", 15" and 19" as well as a variety of interfaces. Fast availability from stock as well as the fanless industrial design complete the concept.

 

Benefits

Future-proof due to latest PC technology

  • Intel Celeron Quad Core Processor (N3160, 1.6 GHz)
  • 4 GB or 8 GB work memory
  • 1 x mPCIe and 1 x mSATA for flexible expansion
  • 2 additional displays can be connected

Attractive visualization with industrial displays in modern design

  • Analog-resistive touch displays in widescreen format in sizes 12", 15" and 19"
  • Flexible mounting – horizontal or vertical, built-in or VESA
  • Metal surround for protection from damage

Easy connection using a variety of interfaces

  • 4 x COM (RS 232/RS 485/RS 422)
  • 4 x USB - of which 2 x USB 3.0
  • 2 x Gbit LAN (teaming-capable)
  • 1 x DisplayPort & 1 x VGA

Proven reliability due to "Made for Industry" & SIMATIC quality

  • Fanless, closed industrial design (front IP65, enclosure IP40)
  • Run-in tested for fast and trouble-free commissioning
  • Certificates for worldwide use

Economic solutions and fast availability

  • Ideal platform for cost-optimized PC and HMI applications in the industrial environment
  • Attractive packages with SIMATIC HMI software
  • Many configurations available directly ex stock
 

Application

The IPC377E is versatile and can be used in factory automation, warehousing and logistics as well as in assembly workstations, for example.

Areas that can be covered by the applications include the following:

  • HMI applications
  • Data collection (e.g. production and energy data)
  • Production networking and communication
  • Easy image processing
  • Simple control tasks
 

Design

Operator control unit

  • Touch screen: Analog-resistive
  • Front IP65 degree of protection

12" touch

  • Resolution: 1 280 x 800

15" touch

  • Resolution: 1 366 x 768

19" touch

  • Resolution: 1 366 x 768

Basic design

  • All-metal enclosure with IP40 degree of protection
  • Integrated 24 V DC power supply
  • Processor:
    Intel Celeron N3160, 1.6 GHz – burst frequency 2.24 GHz, Quad Core
  • Interfaces:
    • 2 x Gbit Ethernet (RJ45)
    • 2 x USB 3.0; 2 x USB 2.0
    • 4 x COM, of which 2 x in BIOS selectable between RS 232 / RS 485 / RS 422
    • Audio in/out
  • Video interfaces:
    • 1 x DisplayPort & 1 x VGA
    • Expansion options
    • 1 x mPCIe (half-size)
    • 1 x mSATA (full-size)

Design versions

  • Main memory configuration
    • 4 GB or 8 GB RAM
  • Mass storage
    • Without mass storage
    • 500 GB HDD
    • 256 GB SSD
  • Preinstalled operating systems:
    • Without operating system
    • Windows 7 Ultimate 64-bit, MUI

Versions – available directly ex stock

Each in 3 display sizes, 12", 15" or 19":

  • Work memory: 4 GB
  • Mass storage: 500 GB HDD or 256 GB SSD
  • Operating system: without OS or with Windows 7 Ultimate, 64-bit, MUI preinstalled and activated
 

Technical specifications

Article number

6AV7230-0....-....

 

SIMATIC IPC377E

Installation type/mounting

 

Mounting

Panel mount and VESA, horizontal and vertical

Design

Panel PC, built-in unit

Supply voltage

 

Type of supply voltage

24 V DC

Mains buffering

 

  • ● Mains/voltage failure stored energy time

10 ms

Processor

 

Processor type

Intel Celeron N3160

Drives

 

Hard disk

500 GB HDD

SSD

Yes; 256 GB SSD

Memory

 

Type of memory

DDR3L

Main memory

4 GB, 8 GB

Capacity of main memory, max.

8 Gbyte

Hardware configuration

 

Slots

 

  • ● free slots

1x mPCIe (half-size), 1x mSATA (full-size)

Interfaces

 

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

USB port

2x USB 2.0, 2x USB 3.0 (high current)

Video interfaces

 

  • ● Graphics interface

1x DisplayPort, 1x VGA

Industrial Ethernet

 

  • ● Industrial Ethernet interface

2 x Ethernet (RJ45)

  • — 100 Mbps

Yes

  • — 1000 Mbps

Yes

Protocols

 

Protocols (Ethernet)

 

  • ● TCP/IP

Yes

Integrated Functions

 

Monitoring functions

 

  • ● Temperature monitoring

Yes

  • ● Watchdog

Yes

  • ● Status LEDs

POWER, HDD

  • ● Fan

No

EMC

 

Interference immunity against discharge of static electricity

 

  • ● Interference immunity against discharge of static electricity

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

  • ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

 

  • — Test voltage at air discharge

8 kV

  • — Test voltage at contact discharge

6 kV

Interference immunity against high-frequency electromagnetic fields

 

  • ● Interference immunity against high frequency radiation

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

Interference immunity to cable-borne interference

 

  • ● Interference immunity on supply cables

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

  • ● Interference immunity on signal cables >30m

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

  • ● Interference immunity on signal cables < 30m

±1 kV acc. to IEC 61000-4-4, Burst

Interference immunity against voltage surge

 

  • ● asymmetric interference

±2 kV acc. to IEC 61000-4-5, surge asymmetric

  • ● symmetric interference

±1 kV acc. to IEC 61000-4-5, surge symmetric

Interference immunity to magnetic fields

 

  • ● Interference immunity to magnetic fields at 50 Hz

100 A/m; to IEC 61000-4-8

Degree and class of protection

 

IP (at the front)

IP65

IP (rear)

IP40

Standards, approvals, certificates

 

CE mark

Yes

UL approval

Yes

cULus

Yes

RCM (formerly C-TICK)

Yes

EAC (formerly Gost-R)

Yes

FCC

Yes

Dust protection

Protection against foreign bodies > 1 mm

Ambient conditions

 

Ambient temperature during operation

 

  • ● Ambient temperature during operation

0 to +45°C

Ambient temperature during storage/transportation

 

  • ● min.

-20 °C

  • ● max.

60 °C

Relative humidity

 

  • ● Relative humidity

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Vibrations

 

  • ● Vibration resistance during operation acc. to IEC 60068-2-6

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Shock testing

 

  • ● Shock load during operation

Tested in accordance with IEC 60068-2-27: With SSD: 150 m/s², 11 ms; with HDD: 9.8 m/s², 20 ms

Operating systems

 

Operating system

Windows 7 Ultimate (Multi-Language), 64-bit; Windows 10 Enterprise LTSB 2016, 64-bit

pre-installed operating system

Yes

without operating system

Yes

 

Article number

6AV7230-0CA20-0BA0

6AV7230-0CA20-1BA0

6AV7230-0DA20-0BA0

6AV7230-0DA20-1BA0

6AV7230-0EA20-0BA0

6AV7230-0EA20-1BA0

 

SIMATIC IPC377E, 12" TOUCH

SIMATIC IPC377E, 12" TOUCH

SIMATIC IPC377E, 15" TOUCH

SIMATIC IPC377E, 15" TOUCH

SIMATIC IPC377E, 19" TOUCH

SIMATIC IPC377E, 19" TOUCH

Installation type/mounting

 

 

 

 

 

 

Mounting

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Design

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Supply voltage

 

 

 

 

 

 

Type of supply voltage

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

Mains buffering

 

 

 

 

 

 

  • ● Mains/voltage failure stored energy time

10 ms

10 ms

10 ms

10 ms

10 ms

10 ms

Processor

 

 

 

 

 

 

Processor type

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Drives

 

 

 

 

 

 

Hard disk

500 GB HDD

500 GB HDD

500 GB HDD

500 GB HDD

500 GB HDD

500 GB HDD

Memory

 

 

 

 

 

 

Type of memory

DDR3L

DDR3L

DDR3L

DDR3L

DDR3L

DDR3L

Main memory

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

Capacity of main memory, max.

8 Gbyte

8 Gbyte

8 Gbyte

8 Gbyte

8 Gbyte

8 Gbyte

Hardware configuration

 

 

 

 

 

 

Slots

 

 

 

 

 

 

  • ● free slots

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

Interfaces

 

 

 

 

 

 

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

USB port

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

Video interfaces

 

 

 

 

 

 

  • ● Graphics interface

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

Industrial Ethernet

 

 

 

 

 

 

  • ● Industrial Ethernet interface

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

  • — 100 Mbps

Yes

Yes

Yes

Yes

Yes

Yes

  • — 1000 Mbps

Yes

Yes

Yes

Yes

Yes

Yes

Protocols

 

 

 

 

 

 

Protocols (Ethernet)

 

 

 

 

 

 

  • ● TCP/IP

Yes

Yes

Yes

Yes

Yes

Yes

Integrated Functions

 

 

 

 

 

 

Monitoring functions

 

 

 

 

 

 

  • ● Temperature monitoring

Yes

Yes

Yes

Yes

Yes

Yes

  • ● Watchdog

Yes

Yes

Yes

Yes

Yes

Yes

  • ● Status LEDs

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

  • ● Fan

No

No

No

No

No

No

EMC

 

 

 

 

 

 

Interference immunity against discharge of static electricity

 

 

 

 

 

 

  • ● Interference immunity against discharge of static electricity

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

  • ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

 

 

 

 

 

 

  • — Test voltage at air discharge

8 kV

8 kV

8 kV

8 kV

8 kV

8 kV

  • — Test voltage at contact discharge

6 kV

6 kV

6 kV

6 kV

6 kV

6 kV

Interference immunity against high-frequency electromagnetic fields

 

 

 

 

 

 

  • ● Interference immunity against high frequency radiation

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

Interference immunity to cable-borne interference

 

 

 

 

 

 

  • ● Interference immunity on supply cables

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

  • ● Interference immunity on signal cables >30m

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

  • ● Interference immunity on signal cables < 30m

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

Interference immunity against voltage surge

 

 

 

 

 

 

  • ● asymmetric interference

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

  • ● symmetric interference

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

Interference immunity to magnetic fields

 

 

 

 

 

 

  • ● Interference immunity to magnetic fields at 50 Hz

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

Degree and class of protection

 

 

 

 

 

 

IP (at the front)

IP65

IP65

IP65

IP65

IP65

IP65

IP (rear)

IP40

IP40

IP40

IP40

IP40

IP40

Standards, approvals, certificates

 

 

 

 

 

 

CE mark

Yes

Yes

Yes

Yes

Yes

Yes

cULus

No

No

No

No

No

No

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Yes

Yes

Yes

FCC

Yes

Yes

Yes

Yes

Yes

Yes

Dust protection

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Ambient conditions

 

 

 

 

 

 

Ambient temperature during operation

 

 

 

 

 

 

  • ● Ambient temperature during operation

0 to +40 °C

0 to +40 °C

0 to +40 °C

0 to +40 °C

0 to +40 °C

0 to +40 °C

Ambient temperature during storage/transportation

 

 

 

 

 

 

  • ● min.

-20 °C

-20 °C

-20 °C

-20 °C

-20 °C

-20 °C

  • ● max.

60 °C

60 °C

60 °C

60 °C

60 °C

60 °C

Relative humidity

 

 

 

 

 

 

  • ● Relative humidity

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Vibrations

 

 

 

 

 

 

  • ● Vibration resistance during operation acc. to IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s²; tested according to DIN IEC 60068-2-6

Shock testing

 

 

 

 

 

 

  • ● Shock load during operation

With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s², 20 ms; tested according to IEC 60068-2-27

Operating systems

 

 

 

 

 

 

without operating system

Yes

Yes

Yes

Yes

Yes

Yes

Dimensions

 

 

 

 

 

 

Width

320 mm

320 mm

406 mm

406 mm

472.6 mm

472.6 mm

Height

225.6 mm

225.6 mm

258.1 mm

258.1 mm

296.8 mm

296.8 mm

Depth

95.2 mm

95.2 mm

103 mm

103 mm

103 mm

103 mm

 

Article number

6AV7230-0CA20-0CA0

6AV7230-0CA20-1CA0

6AV7230-0DA20-0CA0

6AV7230-0DA20-1CA0

6AV7230-0EA20-0CA0

6AV7230-0EA20-1CA0

 

SIMATIC IPC377E, 12" TOUCH

SIMATIC IPC377E, 12" TOUCH

SIMATIC IPC377E, 15" TOUCH

SIMATIC IPC377E, 15" TOUCH

SIMATIC IPC377E, 19" TOUCH

SIMATIC IPC377E, 19" TOUCH

Installation type/mounting

 

 

 

 

 

 

Mounting

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Design

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Supply voltage

 

 

 

 

 

 

Type of supply voltage

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

Mains buffering

 

 

 

 

 

 

  • ● Mains/voltage failure stored energy time

10 ms

10 ms

10 ms

10 ms

10 ms

10 ms

Processor

 

 

 

 

 

 

Processor type

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Drives

 

 

 

 

 

 

SSD

Yes; 256 GB SSD

Yes; 256 GB SSD

Yes; 256 GB SSD

Yes; 256 GB SSD

Yes; 256 GB SSD

Yes; 256 GB SSD

Memory

 

 

 

 

 

 

Type of memory

DDR3L

DDR3L

DDR3L

DDR3L

DDR3L

DDR3L

Main memory

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

Capacity of main memory, max.

8 Gbyte

8 Gbyte

8 Gbyte

8 Gbyte

8 Gbyte

8 Gbyte

Hardware configuration

 

 

 

 

 

 

Slots

 

 

 

 

 

 

  • ● free slots

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

Interfaces

 

 

 

 

 

 

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

USB port

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

Video interfaces

 

 

 

 

 

 

  • ● Graphics interface

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

Industrial Ethernet

 

 

 

 

 

 

  • ● Industrial Ethernet interface

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

  • — 100 Mbps

Yes

Yes

Yes

Yes

Yes

Yes

  • — 1000 Mbps

Yes

Yes

Yes

Yes

Yes

Yes

Protocols

 

 

 

 

 

 

Protocols (Ethernet)

 

 

 

 

 

 

  • ● TCP/IP

Yes

Yes

Yes

Yes

Yes

Yes

Integrated Functions

 

 

 

 

 

 

Monitoring functions

 

 

 

 

 

 

  • ● Temperature monitoring

Yes

Yes

Yes

Yes

Yes

Yes

  • ● Watchdog

Yes

Yes

Yes

Yes

Yes

Yes

  • ● Status LEDs

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

  • ● Fan

No

No

No

No

No

No

EMC

 

 

 

 

 

 

Interference immunity against discharge of static electricity

 

 

 

 

 

 

  • ● Interference immunity against discharge of static electricity

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

±6 kV contact; ±8 kV air (to IEC 1000-4-2; ESD)

  • ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

 

 

 

 

 

 

  • — Test voltage at air discharge

8 kV

8 kV

8 kV

8 kV

8 kV

8 kV

  • — Test voltage at contact discharge

6 kV

6 kV

6 kV

6 kV

6 kV

6 kV

Interference immunity against high-frequency electromagnetic fields

 

 

 

 

 

 

  • ● Interference immunity against high frequency radiation

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

Interference immunity to cable-borne interference

 

 

 

 

 

 

  • ● Interference immunity on supply cables

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

±2 kV (according to IEC 61000-4-4, burst); ±1 kV (according to IEC 61000-4-5, surge pulse/line to line); ±2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

  • ● Interference immunity on signal cables >30m

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

±2 kV acc. to IEC 61000-4-4, burst; ±2 kV acc. to IEC 61000-4-5, surge

  • ● Interference immunity on signal cables < 30m

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

±1 kV acc. to IEC 61000-4-4, Burst

Interference immunity against voltage surge

 

 

 

 

 

 

  • ● asymmetric interference

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

±2 kV acc. to IEC 61000-4-5, surge asymmetric

  • ● symmetric interference

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

±1 kV acc. to IEC 61000-4-5, surge symmetric

Interference immunity to magnetic fields

 

 

 

 

 

 

  • ● Interference immunity to magnetic fields at 50 Hz

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

100 A/m; to IEC 61000-4-8

Degree and class of protection

 

 

 

 

 

 

IP (at the front)

IP65

IP65

IP65

IP65

IP65

IP65

IP (rear)

IP40

IP40

IP40

IP40

IP40

IP40

Standards, approvals, certificates

 

 

 

 

 

 

CE mark

Yes

Yes

Yes

Yes

Yes

Yes

UL approval

Yes

Yes

Yes

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Yes

Yes

Yes

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Yes

Yes

Yes

FCC

Yes

Yes

Yes

Yes

Yes

Yes

Dust protection

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Ambient conditions

 

 

 

 

 

 

Ambient temperature during operation

 

 

 

 

 

 

  • ● Ambient temperature during operation

0 to +45°C

0 to +45°C

0 to +45°C

0 to +45°C

0 to +45°C

0 to +45°C

  • ● min.

0 °C

0 °C

0 °C

0 °C

0 °C

0 °C

  • ● max.

45 °C

45 °C

45 °C

45 °C

45 °C

45 °C

Ambient temperature during storage/transportation

 

 

 

 

 

 

  • ● min.

-20 °C

-20 °C

-20 °C

-20 °C

-20 °C

-20 °C

  • ● max.

60 °C

60 °C

60 °C

60 °C

60 °C

60 °C

Relative humidity

 

 

 

 

 

 

  • ● Relative humidity

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation)

Vibrations

 

 

 

 

 

 

  • ● Vibration resistance during operation acc. to IEC 60068-2-6

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)

Shock testing

 

 

 

 

 

 

  • ● Shock load during operation

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Tested according to IEC 60068-2-27: 150 m/s², 11 ms

Operating systems

 

 

 

 

 

 

Operating system

 

Windows 7 Ultimate (Multi-Language) 64-bit

 

Windows 7 Ultimate (Multi-Language) 64-bit

 

Windows 7 Ultimate (Multi-Language) 64-bit

pre-installed operating system

 

Yes

 

Yes

 

Yes

without operating system

Yes

 

Yes

 

Yes

 

pre-installed operating system

 

 

 

 

 

 

  • ● Windows 7

 

Yes; Ultimate 64 bit, SP1

 

Yes; Ultimate 64 bit, SP1

 

Yes; Ultimate 64 bit, SP1

Dimensions

 

 

 

 

 

 

Width

320 mm

320 mm

406 mm

406 mm

472.6 mm

472.6 mm

Height

225.6 mm

225.6 mm

258.1 mm

258.1 mm

296.8 mm

296.8 mm

Depth

95.2 mm

95.2 mm

103 mm

103 mm

103 mm

103 mm

경기도 용인시 기흥구 용구대로 1855번길 95(상갈동) (주)에버텍 l 대표자 : 이승진 l 사업자등록번호 : 671-88-00213
: 031-287-6361    : 031-287-6362    : sales@yesevt.com

© k2s0o1d4e0s2i1g5n. All Rights Reserved